PitcoSolsticeandSolsticeSupremeHighEfficiencyGasFryers
SG/SSHSeriesServiceManual 58
ReplacingtheHiLimitThermostat
1. Remove the two (2) bolt clamp screws on the hi-
limit probes using a Phillips screwdriver.
2. Remove the two (2) screws, which hold the
high-limit thermostat, using a Phillips
screwdriver.
3. Remove the two (2) screws, which hold the
wires, using a flathead screwdriver.
4. Replace the high-limit thermostat by following
steps 1 through 3 in reverse.