EasyManua.ls Logo

Pitco SG Series - Replacing the Return Valve

Pitco SG Series
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PitcoSolsticeandSolsticeSupremeHighEfficiencyGasFryers
SG/SSHSeriesServiceManual 60
ReplacingtheReturnValve
IMPORTANT: Oil must be removed from the tank before replacing the return valve.
1. Remove all connections from the 3-way return
valve using a 1/16 inch wrench.
2. Remove the cotter pin on return valve using
needle-nose pliers.
3. Replace the return valve by following steps 1
through 2 in reverse, replacing the cotter pin if
necessary.
NOTE: Thread sealant is not required for
these fittings.

Table of Contents

Other manuals for Pitco SG Series

Related product manuals