4.3.14.3 Event Status
This page allows the user to inspect the current Link OAM Link Event configurations, and change them as well. as
screen in Figure 4-3-14-3 appears.
Figure 4-3-14-3: Link OAM Statistic Page Screenshot
The page includes the following fields:
General Settings
Object Description
• Port
The switch port number.
• Sequence Number
This two-octet field indicates the total number of events occurred at the remote
end.
• Frame Error Event
Timestamp
This two-octet field indicates the time reference when the event was generated,
in terms of 100 ms intervals.
• Frame error event
window
This two-octet field indicates the duration of the period in terms of 100 ms
intervals. 1) The default value is one second. 2) The lower bound is one second.
3) The upper bound is one minute.
• Frame error event
threshold
This four-octet field indicates the number of detected errored frames in the period
is required to be equal to or greater than in order for the event to be generated. 1)

Table of Contents

Other manuals for Planet IGS-5225 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Planet IGS-5225 Series and is the answer not in the manual?

Planet IGS-5225 Series Specifications

General IconGeneral
BrandPlanet
ModelIGS-5225 Series
CategorySwitch
LanguageEnglish

Related product manuals