11-32
11.17 ethernet-oam errored-symbol-period threshold
low
Command:
ethernet-oam errored-symbol-period threshold low <low-symbols>
no ethernet-oam errored-symbol-period threshold low
Function:
Configure the low threshold of errored symbol event, no command restores the default value.
Parameter:
<low-symbols>, the low threshold of errored symbol event, ranging from 1 to
18446744073709551615 symbols.
none, cancel the high threshold configuration.
Default:
1.
Command Mode:
Port mode
Usage Guide:
During the specific detection period, errored symbol event is induced if the number of errored
symbols is larger than or equal to the low threshold and the device notifies the peer by sending
event notification OAMPDU. Note that the low threshold should not be larger than the high
threshold.
Example:
Set the low threshold of errored symbol event on port 1/0/4 to 5.
Switch(Config-If-Ethernet1/0/4)#ethernet-oam errored-symbol-period threshold low 5
11.18 ethernet-oam errored-symbol-period window
Command:
ethernet-oam errored-symbol-period window <seconds>
no ethernet-oam errored-symbol-period window
Function:
Configure the detection period of errored symbol event, no command restores the default value.
Parameter:
<seconds>, the detection period value of errored symbol event, ranging from 1 to 60s.