Switch(config)#interface ethernet 1/0/10
Switch(Config-If-Ethernet1/0/10)#switchport mode trunk
Switch(Config-If-Ethernet1/0/10)#dot1q-tunnel tpid 0x9100
Switch(Config-If-Ethernet1/0/10)#exit
Switch(config)#
12.1.5 garp timer join
Command:
garp timer join <200-500>
Function:
Set the value of garp join timer, note that the value of join timer must be less than half leave timer.
Parameter:
<200-500>, the value of timer in millisecond
Command mode:
Global mode
Default:
200 ms.
Usage Guide:
Check whether the value satisfy the range. If so, modify the value of garp timer to the specified
value, otherwise return a configuration error.
Example:
Set the value of garp join timer as 200ms.
Switch(config)#garp timer join 200
12.1.6 garp timer leave
Command:
garp timer leave <500-1200>
Function:
Set the value of garp leave timer, note that the value of leave timer must be double of join timer and
less than leaveAll timer.
Parameter:
<500-1200>, the value of timer in millisecond
Command mode:
Global mode