Symptom Problem Corrective Action
Voice calls are not coming to the 
SoundStation IP 7000 phone.
The call type is not set correctly. Ensure that the Polycom HDX system has 
an active voice interface installed and it is 
listed as the first interface. Refer to the 
Administrator’s Guide for Polycom HDX 
Systems at 
http://www.polycom.com/videodocumenta
tion.
There is a faulty connection 
between the SoundStation IP 
7000 phone and the Polycom 
HDX system.
Do one of the following:
• Check the cabling.
• Ensure both the Polycom HDX system 
and the SoundStation IP 7000 can 
“see” each other. On the Polycom 
HDX system, go to System > System 
Information. On the phone, press the 
Menu key, and then select Settings > 
Advanced > Admin Settings > 
Voice Call Type.
There is a dial tone, but the call is 
not going through.
Do one of the following:
• Ensure that the Polycom HDX system 
has an active voice interface installed 
and it is listed as the first interface.
• Ensure that the Polycom HDX 
system’s active voice interface is 
connected to an active network.
• Verify the call type:
Press  , and then select 
Settings > Advanced > Admin 
Settings > Voice Call Type.
When prompted for the administrative 
password, enter 456.
The Voice Call Type menu appears.
Verify that the call type is set to Auto.
Setting to HDX Preference should 
not be necessary. Press the Select 
soft key if you change the selection.