Command Protocol Reference Guide
A - 33
Description
This parameter defines the peak hold behavior of all of the peak meters in the
system. If the infinite peak hold mode is selected, the peaks can be reset using
the meter_peak_reset parameter.
meter_peak_reset
Meter Peak Reset
Description
This parameter resets all of the peak meters in the system, if the peak meters
are configured to have the infinite peak hold behavior.
mic_in_gain
Mic Input Pre-Amp Gain
Description
This parameter sets the gain (in dB) of the mic pre-amp. A separate mic/line
control is not provided. Instead, a continuous gain range is provided, and the
firmware will map this to the appropriate mic/line switch and pre-amp gain
settings.
Argument Argument value
Channel Type Global System
Value Type Void
Read/Write Mode Write-Only
Event Source No
Argument Argument value
Channel Type Virtual Channel
Value Type Floating-Point
Read/Write Mode Read/Write
Phys Chans Conferencing Mic/Line Input, Sound Reinforcement Mic/Line
Input
Virt Chans Mono, Stereo
System Limits Minimum: -20.0, Maximum: 64.0, Resolution: 0.5
Default 0.0
User Limits
Supported
No
Event Source No