Description
This parameter sets the amount of time (in milliseconds) it takes the compres-
sor to ramp the gain up to the target gain once the input signal level drops
below the compressor threshold.
dp_comp_en
Enable Compressor
Description
This parameter enables (1) or disables (0) the compressor function of the
dynamics processor. This parameter and dp_en must be enabled for the com-
pressor to function.
dp_comp_ratio
Compressor Ratio
System Limits Minimum: 1, Maximum: 2000
Default 100
User Limits
Supported
No
Event Source No
Argument Argument value
Argument Argument value
Channel Type Virtual Channel
Value Type Boolean
Read/Write Mode Read/Write
Phys Chans
Conferencing Mic/Line Input, Conferencing Line Output,
Sound Reinforcement Mic/Line Input, Sound Reinforcement
Line Output, Analog Telephony Input, Analog Telephony
Output, Submix, ConferenceLink Aux Input, ConferenceLink
Aux Output
Virt Chans Mono, Stereo
Default 0
Event Source No
Argument Argument value
Channel Type Virtual Channel
Value Type Floating-Point
Read/Write Mode Read/Write

Table of Contents

Other manuals for Polycom SoundStructure C8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom SoundStructure C8 and is the answer not in the manual?

Polycom SoundStructure C8 Specifications

General IconGeneral
BrandPolycom
ModelSoundStructure C8
CategoryConference System
LanguageEnglish

Related product manuals