EasyManua.ls Logo

Potterton Paramount five 80 - Page 65

Potterton Paramount five 80
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Heating circuit 1
Prog. no.
2
(1)
Prog. no.
3
(1)
Prog. no.
Level Standard value
Continuous pump operation
No | Yes
809 1109 1409 E No
Overtemp prot pump circuit
Off | On
820 1120 1420 E Off
Mixing valve boost 830 1130 1430 E 5 °C
Actuator running time 834 1134 1434 E 140 s
Floor curing function
0: Off | 1: Functional heating | 2: Curing heating | 3:
Functional/curing heating | 4: Curing/functional
heating | 5: Manually
850 1150 1450 E Off
Floor curing setp manually 851 1151 1451 E 25 °C
Floor curing setp current 855 1155 1455 E - - - °C
Floor curing day current 856 1156 1456 E - - -
Excess heat draw
0: Off | 1: Heating mode | 2: Always
861 1161 1461 E Heating mode
With buffer
No | Yes
870 1170 1470 E Yes
With prim contr/system pump
No | Yes
872 1172 1472 E Yes
Pump speed reduction
0: Operating level | 1: Characteristic | 2: Temp
differential nominal
880 1180 1480 E Characteristic
Pump speed min 882 1182 1482 C 30 %
Pump speed max 883 1183 1483 C 80%
Curve readj at 50% speed 888 1188 1488 E 10 %
Flow setp readj speed ctrl
No | Yes
890 1190 1490 E YesNo
Operating level changeover
0: Protection | 1: Reduced | 2: Comfort
898 1198 1498 E Reduced
Optg mode changeover
0: None | 1: Protection | 2: Reduced | 3: Comfort | 4:
Automatic
900 1200 1500 E Protection
(1) Parameters only visible if heating circuit is installed!
DHW Prog. no. Level Standard value
Nominal setpoint 1610 Eu 55 °C
Reduced setpoint 1612 E 45 °C
Nominal setpoint max 1614 E 65 °C
Release
24h/day | Time programs HCs | Time program 4/DHW
1620 Eu Time program
4/DHW
Charging priority
0: Absolute 1: | Shifting | 2: None | 3: MC shifting, PC absolute
1630 E MC shifting, PC
absolute
Legionella function
0: Off | 1: Periodically | 2: Fixed weekday
1640 E Fixed weekday
Legionella funct periodically 1641 E 7
Legionella funct weekday
1: Monday | 2: Tuesday | 3: Wednesday | 4: Thursday | 5: Friday | 6: Saturday |
7: Sunday
1642 E Sunday
Legionella funct time 1644 E - - -
Legionella funct setpoint 1645 E 65 °C
Legionella funct duration 1646 E - - - min
Legionella funct circ pump
Off | On
1647 E On
Circulating pump release
1: Time program 3/HCP | 2: DHW release | 3: Time program 4/DHW | 4: Time
program 5
1660 C DHW release
9 Settings
7703046 - 01 - 23072018 Paramount five 30 – 115 65

Table of Contents

Related product manuals