Boiler Prog. no. Level Standard value
Controller delay duration 2453 E 40 s
Switching diff on HCs 2454 E 4 °C
Switching diff off min HCs 2455 E 5 °C
Switching diff off max HCs 2456 E 10 °C
Switching diff on DHW 2460 E 5 °C
Switching diff off min DHW 2461 E 6 °C
Switching diff off max DHW 2462 E 8 °C
Delay heat req special op 2470 E 0 s
Static press superv sh'down
0: Start prevention | 1: Lockout position
2480 E Lockout position
Gas energy metering
Off | On
2550 C Off
Gas energy metering readj 2551 C 1.0
Off delay flue gas damper 2560 E 30 s
(1) the kW settings are approximate values. Exact values can be determined by the gas meter for example.
Cascade Prog. no. Level Standard value
Lead strategy
1: Late on, early off | 2: Late on, late off | 3: Early on, late off |
3510 E Late on, late off
Release integral source seq 3530 E 50 °C*min
Reset integral source seq 3531 E 20 °C*min
Restart lock 3532 E 300 s
Switch on delay 3533 E 10 min
Switch-on delay DHW 3535 E 2 min
Auto source seq ch'over 3540 E 100 h
Auto source seq exclusion
0: None | 1: First | 2: Last | 3: First and last
3541 E None
Leading source
1: Source 1 | 2: Source 2 | 3: Source 3 | 4: Source 4 | 5: Source 5 | 6: Source 6 |
7: Source 7 | 8: Source 8 | 9: Source 9 | 10: Source 10 | 11: Source 11 | 12:
Source 12 | 13: Source 13 | 14: Source 14 | 15: Source 15 | 16: Source 16
3544 E Source 1
Return setpoint min 3560 E 8 °C
Temp differential min 3590 E - - - °C
Solar Prog. no. Level Standard value
Temp diff on 3810 C 8 °C
Temp diff off 3811 C 4 °C
Charg temp min DHW st tank 3812 E - - - °C
Temp diff on buffer 3813 E - - - °C
Temp diff off buffer 3814 E - - - °C
Charging temp min buffer 3815 E - - - °C
Temp diff on swi pool 3816 E - - - °C
Temp diff off swi pool 3817 E - - - °C
Charging temp min swi pool 3818 E - - - °C
Charging prio storage tank
0: None | 1: DHW storage tank | 2: Buffer storage tank
3822 E DHW storage tank
Charging time relative prio 3825 E - - - min
Waiting time relative prio 3826 E 5 min
Waiting time parallel op 3827 E - - - min
Delay secondary pump 3828 E 60 s
Collector start function 3830 E - - -
Min run time collector pump 3831 E 20 s
Collector start function on 3832 E 07:00 (h:min)
Collector start function off 3833 E 19:00 (h:min)