Carrying out measurements
Important notices
Always remove the measuring leads  from the object being tested
before switching over to a new function or a different area of measure-
ment.
The device may only be used in a dry and clean environment. Dirt and
moisture diminish the insulation resistances and this could, especially
with large voltages, lead to you receiving an electric shock.
The device may only be utilised within the given measurement ranges.
Before being taken into use, the device must be tested for correct func-
tioning (e.g. on a known current or voltage source).
Steps are to be taken to ensure that the measuring leads  are in a
faultless condition.
For voltage measurements use exclusively the input sockets
VΩ
7
and COM
8
and, for measurement of electrical current intensity,
exclusively the sockets
COM
8
and 2A
0
resp. COM
8
and mA °C
9
.
Connect the measuring leads  correctly and appropriate to their
polarity.
The device has an automatic polarity function.
If the object being tested is not correctly connected to the multimeter
with the regard to polarity, the indicated measurement value is preceded by
a minus sign.
With component measurements, the component being tested may not be
located within a switching, as this would falsify the measurement results.