- 36 -
Impulse range measurement
Measuring temperature
Air humidity measurement
Sound measurement
Measurement Range Resolution Precision
35-100 dB 0,1 dB +/- 5,0 dB
(at 94 dB, 1kHz sine wave)
Measurement Range Resolution Precision
30-90% 0,1% +/- 8,0%
Measurement Range Resolution Precision
-20 - 0 °C 0,1 °C +/- (5% f.m.r. +/- 3 points)
0 - 20 °C +/- (3% f.m.r. +/- 3 points)
20 - 400 °C +/- (3% f.m.r. +/- 5 points)
-20 - 0 °C 1 °C +/- (5% f.m.r. +/- 5 points)
0 - 400 °C +/- (1% f.m.r. +/- 3 points)
400 - 1000 °C +/- (3% f.m.r. +/- 3 points)
Measurement Range Resolution Precision
0,1 - 99,9% 0,1% +/- 3,0%