- 35 -
Measuring condensors
Overload protection: 250 V /
~
RMS
Frequency measurement
Measurement ranges: 0,5 V - 10 V
~
RMS, 0 Hz to 200 kHz
Measurement Range Resolution Precision
9,999 Hz 0,001 +/- (0,2% f.m.r. +/- 5 points)
99,99 Hz 0,01 +/- (0,2% f.m.r. +/- 5 points)
999,9 Hz 0,1
9,999 kHz 1 Hz
99,99 kHz 10 Hz +/- (0,2% f.m.r. +/- 5 points)
199,99 kHz 100 Hz
>200 kHz To be read only as a reference value.
Measurement Range Resolution Precision
4 nF 1 pF +/- (4,0% f.m.r. +/- 8 points)
40 nF 10 pF
400 nF 0,1 nF
4 µF 1 nF
40 µF 10 nF
200 µF 100 nF +/- (8,0% f.m.r. +/- 10 points)
IB_KH3322_Bn23558_LB4c 26.08.2008 14:57 Uhr Seite 35