Measuring continuity
Caution!
Before attachment of the measurement leads, the object being tested must
be de-energised, so as not to damage the device or the object being tested. In
cases of doubt, the freedom from energy must be proved by measurement.
Place the function switch
q
at the position .
If necessary, press the button
FUNC.
r
until the indicator appears in
the display
z
.
Insert the measuring leads  into the input sockets
VΩ
7
and COM
8
.
Connect the measurement prods with the object being tested.
When a continuity is extant resp. with resistances of less 40 Ω, a signal
tone sounds.
Note:
For checking the continuity of your measurement leads , connect the
two measurement prods with each other.
IB_KH3322_Bn23558_LB4c 26.08.2008 14:57 Uhr Seite 24