First connect a measuring lead to the earth and THEN the other measuring
lead to the live wire. When disconnecting the measuring leads , di-
sconnect first of all the lead connected to the live wire.
When working with the measurement prods, keep your fingertips
BEHIND the finger protectors on the prods.
Before opening the battery compartment cover, remove the measuring
leads  from the multimeter.
Do not use the multimeter if the battery compartment cover or parts of
the housing are not assembled or have become loose.
To avoid incorrect measurement values, which could lead to electric
shocks or injuries, replace the batteries as soon as the indicator for
weak batteries ( ) resp. drained batteries ( ) is displayed.
For the power supply of the multimeter use exclusively 9 V block batteries
of the type 6F22/6LR61 and insert them into the battery compartment
correctly.
Caution!
To avoid damage to the multimeter and/or the object being tested, pay
heed to the following instructions:
• Before continuity, diode, frequency and resistance measurements, switch
off the power supply to the object being tested and discharge all high-
voltage condensors.
• For current measurements, switch off the power supply to the object
being tested before connecting the multimeter to it.