Operation
31
Powerware
®
5125 Two-in-One (2400–3000 VA) User’s Guide : www.powerware.com
Normal Mode
During Normal mode, the
indicator illuminates and the front panel
displays the percentage of UPS load capacity being used by the protected
equipment (see Figure 19). The UPS monitors and charges the batteries
as needed and provides power protection to your equipment.
>100%
76–100%
51–75%
26–50%
0–25%
Figure 19. Load Level Indicators
When all of the load level indicators and the indicator are
illuminated, power requirements exceed UPS capacity; see page 53 for
more information.
Battery Mode
When the UPS is operating during a power outage, the alarm beeps once
every five seconds and the
indicator illuminates. When the utility
power returns, the UPS switches to Normal mode operation while the
battery recharges.
If battery capacity becomes low while in Battery mode, the
indicator
starts flashing and the alarm continues to beep every five seconds.
Immediately complete and save your work to prevent data loss and
similar difficulties. When utility power is restored after the UPS shuts
down, the UPS automatically restarts.