Chapter 2 Standard specifications
10
Displays current temperature IGBT
Instantaneous power-
down restart
Less than 15 milliseconds: Continuous operation.
More than 15 milliseconds: Automatic detection of motor
speed, instantaneous power-down restart.
Speed start tracking
method
The inverter automatically tracks motor speed after it
starts
Parameter protection
function
Protect inverter parameters by setting administrator
Password and decoding
Monitoring objects including: Running frequency, set
frequency, bus voltage, output voltage, output current,
output power, output torque, input terminal status, output
terminal status, analog AI1 value, analog AI2 value, motor
Actual running speed,PID set value percentage, PID
feedback value percentage.
At most save three error message, and the time, type,
voltage, current, frequency and work status can be queried
when the failure is occurred.
Key lock and function
selection
Lock part or all of keys, define the function scope of some
keys to prevent misuse.
Is completely isolated RS485 communication module,
realize communication with PC connected to the Internet
-10 ℃ to 40 ℃ (temperature at 40 ℃ to 50 ℃, please
derating for use)
Less than 90% R.H, no condensation.
Indoor where no sunlight or corrosive, explosive gas and
water vapor, dust, flammable gas, oil mist, water vapor,
drip or salt, etc.
Product adopts safety
standards.
Product adopts EMC
standards.