Chapter 5 Function parameter
25
Frequency source
auxiliary setting
Reference object
selection for frequency
source auxiliary setting
0. Relative to maximum frequency
1.Relative to master frequency source
A
Frequency source
auxiliary setting range
Frequency source
superimposed selection
Units digit: frequency source
selection
Tens digit: Arithmetic relationship of
master and auxiliary for frequency
source
Frequency source offset
frequency when
superimposing
0.00Hz to F0.19(Maximum
frequency)
Shutdown memory
selection for digital set
frequency
0: W/O memory
1: W/ memory
Frequency command UP
/ DOWN reference
when running
0: Running frequency
1: Set frequency
0.Keyboard control (LED off)
1.Terminal block control (LED on)
2.Communications command control
(LED flashes)
3. Keyboard control+
Communications command control
4. Keyboard control+
Communications command control+
Terminal block control
Binding frequency
source for command
source
Units digit: binding frequency source
selection for operation panel
command
Tens digit: Terminal command
binding frequency source selection (0
to 9, same as units digit)
Hundreds digit: Communication
command binding frequency source
selection (0 to 9, same as units digit)
Ac/Deceleration time
unit
0:1 second; 1:0.1 second
2:0.01 second