Chapter 5 Function parameter
43
Chapter 5
356
E2.29
PID Automatically reduced
frequency selection
0:Invalid;1:Valid
1
357
E2.30
PID stop frequency
0.00HzMaximum frequency
(F0.19)
25
358
E2.31
PID Detection time
0s3600s
10
359
E2.32
PID Detection times
10500
20
5-1-18.E3 Group Virtual DIVirtual DO
No.
Code
Parameter name
Setting range
Factory
setting
Change
360
E3.00
Virtual VDI1 terminal
function selection
0 to 50
0
361
E3.01
Virtual VDI2 terminal
function selection
0 to 50
0
362
E3.02
Virtual VDI3 terminal
function selection
0 to 50
0
363
E3.03
Virtual VDI4 terminal
function selection
0 to 50
0
364
E3.04
Virtual VDI5 terminal
function selection
0 to 50
0
365
E3.05
Virtual VDI terminal status set
Units digit:Virtual VDI1
Tens digit:Virtual VDI2
Hundreds digit:Virtual VDI3
Thousands digit:Virtual VDI4
Tens of thousands:Virtual
VDI5
00000
366
E3.06
Virtual VDI terminal effective
status set mode
Units digit:Virtual VDI1
Tens digit:Virtual VDI2
Hundreds digit:Virtual VDI3
Thousands digit:Virtual VDI4
Tens of thousands:Virtual
VDI5
11111
367
E3.07
AI1 terminal as a function
selection of DI
0 to 50
0
368
E3.10
AI as DI effective mode
selection
Units digit:AI1
0:High level effectively
1:Low level effectively
Tens digit: Hundreds digit:
Reserved
000
369
E3.11
Virtual VDO1 output function
selection
0 to 40
0
370
E3.12
Virtual VDO2 output function
selection
0 to 40
0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Powtran PI160 Series and is the answer not in the manual?

Powtran PI160 Series Specifications

General IconGeneral
BrandPowtran
ModelPI160 Series
CategoryInverter
LanguageEnglish

Related product manuals