Chapter 5 Function parameter
95
4 stage ac/deceleration time selection
5 stage ac/deceleration time selection
6 stage ac/deceleration time selection
7 stage ac/deceleration time selection
8 stage ac/deceleration time selection
9 stage ac/deceleration time selection
10 stage running time T10
10 stage ac/deceleration time selection
11 stage running time T11
11 stage ac/deceleration time selection
12 stage running time T12
12 stage ac/deceleration time selection
13 stage running time T13
13 stage ac/deceleration time selection
14 stage running time T14
14 stage ac/deceleration time selection
15 stage running time T15
15 stage ac/deceleration time selection
Multi-speed operation and deceleration time selection 0 to 3 , corresponding to the
function code:
0: F0.13、F0.14; 1:F7.08、F7.09; 2:F7.10、F7.11; 3:F7.12、F7.13
Multi-stage command 0
reference manner
Function code E1.00 reference
Panel potentiometer reference
High-speed pulse reference
Keyboard set frequency (F0.01)
reference, UP/DOWN can be
modified
This parameter determines the multi-stage command 0 reference channel.
The multi-stage command0 not only can select E1.00, but also there are a variety of other
options so as to facilitate switching between the multi-stage command and the other reference
manner.
5-2-17.E2 group PID function
PID control is a commonly used method of process control, a closed loop system is formed by
the proportional, integral and differential operation of difference between the controlled value
feedback signal and target value signal and by adjusting the inverter output frequency so as to
stabilize the controlled value at the position of the target value.Suitable for flow control, pressure
control and temperature control and other process control applications.