Weekly Task Instruction
(parameter controls, HHR, Stop key. etc.).
Note:1). Perform test with incline set to maximum level and power OFF and power cord dis-
connected.
Monthly
Perform the following maintenance tasks every month.
Monthly Task Instruction
Verify the Safety clip is attached to the
lanyard and functional.
Pull on the lanyard attached to the Safety clip
which trips the Restart (Stop/Restart) switch. The
"PUSH TO RESET SWITCH" message is shown
and an arrow pointing to the Restart switch. Tread-
mill slows and stops.
Inspect the power cord for damage and
that the cord clamp is securely
installed
1
.
Inspect the power cord, make sure it is not dam-
aged or underneath the treadmill. Verify the cord
clamp is securely installed.
Visually inspect the running belt and
deck condition.
Make sure the deck and belt are in good condition,
replace as necessary.
Clean the treadmill’s frame using a cloth
dampened with an approved cleaning
solution
1
.
Use only approved plastic cleaners, see "General
Information" on page3.
Clean outer surface of running belt
1
. Use a soft nylon scrub brush to clean the outer sur-
face of the running belt.
Clean drive motor and pulleys
1
. Remove hood and use wire brush to clean belt and
pulley grooves.
Vacuum debris from around motor, pul-
leys, and floor underneath the
treadmill
1
.
Remove hood. Use a vacuum cleaner (recom-
mended with static protection feature) to clean
debris and lint from front area under the front
cover. Be careful not to bring the nozzle to close to
any electronic circuit boards.
Inspect visible welds, frame, and wire
connections
1
.
Do a visual check of welds and frame. Check for
loose wire connections.
Check for loose fasteners
1
. Check all fasteners and clips for proper tightness
and torque.
Perform functional test to verify all fea-
tures are performing properly
2
.
Verify the unit available functions and programs.
Do the Operation verification procedure, see
"Operation Verification" on page8.
Note:1). Perform task with power removed and incline set to maximum level.
2) Diagnostic tests will vary depending on console model.
Quarterly
Perform the following maintenance tasks every 3 months:
(Undefined variable: TRM700-16Base.ServiceManualTitle)
98
7 Preventative Maintenance
Maintenance Schedule