l Press either the STOP, PAUSE, or RESET key.
l Sequentially type in the service access code using the following control keys to rep-
resent an equivalent numeric value:
1 = Workouts key
5 = Enter key
6 = Up key
7 = Down key
NOTE: The access code must be correctly and quickly entered or the process will
abort. Restart the process from the beginning if this occurs.
P80 Consoles
To access the service software:
l Make sure the P80 is set to the Welcome home page.
l Press and continue holding down the PAUSE key while pressing the Volume and
Channel Up/Down keys in the following sequence ("X" pattern) to open the service soft-
ware login page:
Press/hold PAUSE while selecting CH Up > Vol Down > Vol Up > CH Down
NOTE: Keep the keypad entry interval to greater than 1 second between
key presses. Key press interval speed faster than 1 second may result in an
unsuccessful login. .
l Successful login will open the service access login page. Use the touch-screen keypad
to type in the service access code > Continue to open the functional mode software.
(Undefined variable: TRM700-16Base.ServiceManualTitle)