© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law Page 108
The Main Vented Access Cover & Components
Behind the main vented access cover, are 3 components that can be replaced in the field (the DC Power
Splitter Cable, the TV Tuner USB Cable, and the Heart Rate Board), plus the Headphone Board at the
bottom of the console.
Figure 64: Main Vented Access Cover
The DC Power Splitter is used only in earlier hardware revisions of P80 consoles. It splits the power
between the TV Tuner and the rest of the console.
The TV Tuner USB Cable connects the TV tuner to the top USB port. It is routed behind the mounting
plate portion of the armor to avoid getting pinched by the mounting plate.
The Heart Rate Board snaps into clips in the console, and connects with 2 cables. There is a 3 pin cable
connector at the bottom of the board that leads behind the armor, and there is a 4 pin cable connector at
the top of the board that leads to the heart rate grips.
The Headphone Board connects via a signal cable and a ground wire that snaps onto a ground lug. The
board then snaps into a plastic housing that then snaps onto the bottom of the console.

Table of Contents

Other manuals for Precor P80

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Precor P80 and is the answer not in the manual?

Precor P80 Specifications

General IconGeneral
BrandPrecor
ModelP80
CategoryMusic Mixer
LanguageEnglish

Related product manuals