LOW AIR PRESSURE
The machine pneumatic pressure is low.
Check the pneumatic supply.
Ensure 80 PSI is available.
BRUSH AND CUTTER
NOT HOME The brush and cutter are not home.
Cycle the brush and cutter.
Check why the brush and cutter
can’t reach the home position.
OBSTACLE DETECTED
The tower has an obstruction.
Check for a mechanical bind.
Clear the cause of the fault.
Reset and restart, when ready.
MULTISTRETCH VFD
NOT READY
The indicated VFD is not ready to run.
Check the fault code on the VFD
display in the electrical cabinet.
See VFD manual for fault code
information.
MAIN DRIVE VFD NOT
READY
CARRIAGE VFD NOT
READY
(NAME) CONVEYOR
VFD NOT READY
X2X
COMMUNICATION
ERROR
There is an X2X communication fault, press and
release the E-stop button to clear the fault.
Contact Orion Packaging if
problem persists.
RS485
COMMUNICATION
ERROR
There is an RS485 communication fault, press
and release the E-stop button to clear the fault.
Contact Orion Packaging if
problem persists.
Table 3-33. The Information and Alarm Displays (Continued)
MESSAGE DESCRIPTION CORRECTION