CAUTION!
The pump maintains the stroke rate when changing over
from
„Manual“
operating mode to
„Contact“
operating
mode.
The stroke rate can also be set in „Contact“ operating
mode. It should normally be set to the maximum stroke
rate.
Continuous
display
Memory
Off
On
Main menu
Mode
Settings
Service
Information
Language
Settings
Contact
Auxiliary freq.
Calibrate
Dosing
Relay
Contact
Memory
Factor
End
1.00
Factor
Contact
Memory
Factor
End
1.00 0 0 1 . 0 0
The number of strokes per pulse depends on the factor which you can
input. By using a factor you can multiply incoming pulses by a factor
between 1.01 and 100.00 or reduce them by a factor of 0.01 to 1.00:
Number of strokes executed = factor x number of
incoming pulses
Setting
47