Chapter 3: Management
37
The system returns:
-------------------------------------------------------------------------------------
Time Since Power Up: 1 day 9 hours 46 minutes 36 seconds
Enclosure: SAS JBOD [2U-12Bay or 3U-16 Bay]
I/O Module ID: 1 Max Num Of I/O Modules: 2
FwVersion: 1.07.0000.00 I/O Module Role: Primary
MaxNumOfHDSlots: [12 or 16] MaxNumOfPSUs: 2
MaxNumOfFans: 4 MaxNumOfBlowers: 2
MaxNumOfTempSensors: 8 MaxNumOfVoltageSensors: 5
===========================================
PSU Status Fan1Speed Fan2Speed
===========================================
1 Operational 14735 rpm 15037 rpm
2 Operational 15340 rpm 14361 rpm
===========================================
Blower Status Speed
===========================================
1 Operational 4017 rpm
2 Operational 4066 rpm
===========================================
ID Location Temp Reading ID Location Temp Reading
===========================================
1. Backplane 27C/80F 2. Backplane 28C/82F
3. Backplane 26C/78F 4. Backplane 26C/78F
5. I/O Module1 35C/95F 6. I/O Module1 26C/78F
7. I/O Module2 33C/91F 8. I/O Module2 38C/100F
Thermal Management: Enabled
Allows to shut down the system when critical temperature is reached: Yes
Current minimum fan speed setting: medium low
Enclosure Temp Threshold: 61C/141F (critical) 51C/123F (warning)
Controller Temp Threshold: 71C/159F (critical) 61C/141F (warning)
===========================================
VoltageSensor Voltage
===========================================
13.3V
25.0V
35.0V
4 12.0V
51.1V