VTrak J610s, J310s Product Manual
36
The system returns:
CN#1 Cable Length = 1 meter
CN#2 Cable Length = 3 meter
Note the cable length change for CN2.
Enclosure Command
The Enclosure command:
• Displays information about the J610s or J310s enclosure (below)
• Enables you to make enclosure settings (page 38)
Information List
The Enclosure command displays information about the J610s or J310s
enclosure, including:
The CLI reports information for the I/O module to which it is connected and for
the rest of the components in the J310s enclosure.
Under SAS specifications, both I/O modules are active at the same time. For
management purposes, the default primary I/O module role is Primary. If a
second I/O module is present, its role is Secondary. See the arrow below for I/O
Module Role in the display. Also see “Setting Up Data Cable Connections” on
page 20.
In a J610s or J310s unit with two I/O modules, if the primary I/O module fails or is
removed, the remaining I/O module becomes the default primary I/O module and
assumes the Primary role. If the other I/O module is repaired or replaced, it
becomes the secondary I/O module and assumes the Secondary role.
Viewing Information
To view enclosure information:
cli>enclosure
• Time since power-up
• Enclosure type
• I/O module information
• PSU (power supply) status and
fan speeds
• Blower status and fan speeds
• Temperature sensor readings
• Temperature threshold settings
• Voltage sensor readings
• Expander SAS addresses
• Attached SAS addresses