Chapter 3: Management
39
Automatic Shutdown – Shuts down the VTrak 30 seconds after the
enclosure or controller reaches critical temperature.
Minimum Fan Speed Specifies the minimum fan speed when the VTrak
reaches enclosure or controller warning temperature.
Making Settings
To set the enclosure critical temperature to 61°C (141°F):
cli>enclosure -a mod -s “enc_critical=61”
To enable Thermal Management:
cli>enclosure -a mod -s “thermalmanager=1”
For this command, a 1 enables and a 0 disables.
To enable Automatic Shutdown:
cli>enclosure -a mod -s “allowshutdown=1”
For this command, a 1 enables and a 0 disables.
To set the minimum fan speed to medium high:
cli>enclosure -a mod -s “minfanspeed=3”
For this command:
1 means low
2 means medium-low
3 means medium-high
4 means high
The actual speed depends on the fan manufacturer.
To display a complete list of Enclosure commands:
cli>enclosure -h
Help Command
The VTrak CLI uses the standard Unix online help system.
To access general help:
cli>help