Chapter 3: Management
43
0238 500000E01212F582 CN2
0287 500000E0120B26B2 CN2
0365 5000155FFFC0223E CN2
0462 500000E0114F18F2 CN2
0468 500000E01205B472 CN2
0542 500000E01122C5B2 CN2
0624 500000E0114E4A32 CN2
0639 500000E0114D8E32 CN2
0700 500000E0120B2A62 CN2
0721 500000E0114DE7A2 CN2
0751 500000E0114E5EA2 CN2
0764 500000E0120B28F2 CN2
0765 500000E0114C2342 CN2
0977 500000E0120A2472 CN2
1023 5000155FFFC02408 CN2
The route command displays SAS addresses that are attached to the SAS ports
of the J610s or J310s unit. Three items are reported:
• Entry# – Arbitrary numbers, listed in sequence
• SAS Address – Of the disk drive or other component
• CnID – External SAS port connector number 1 or 2
The device in this example is connected to a J610s unit through connector CN2.
See page 21 for a diagram of connectors on the I/O module.
Route Troubleshooting
If your system returns:
No SAS Routing Entry Exists
...it indicates that no downstream devices are found.
Uptime Command
The uptime command informs you of the elapsed period of time since the J610s
or J310s unit was powered on.
To display uptime:
cli>uptime
The system returns:
System has been running 1 day 9 hours 46 minutes 36 seconds