5.3.2 Installation
1 Insert lower dryer part. Make sure that both slides at the lower part are assembled and pushed
down.
2 Put in the upper dryer part. Insert the lower edge of the upper part carefully into the middle
guidance of the lower part.
3 Check if side plates and gears of upper and lower part fit together correctly.
4 The dryer plate small (2) can now be assembled into the guidance. For this lift dryer plate large
(5) a bit, so that the small plate can be pushed in, completely.
5
Now push both black slides (1) up until the clips click into place.
5.4 Problems and Solutions
5.4.1 Advice on Film Defects
Your processor has been constructed for long term use. If however irregularities might occur, you will
find help to locate the problem below. Please check the listed points, before calling your service-
technician.
5.4.1.1 Films do not have enough density
Bath temperature is too low
Developing time too short
Exposure time is too short
Replenishment rate of developer too low
Developer chemicals are exhausted or too strong diluted: Renew
Fixer solution has been mixed into developer: Renew. Clean and rinse bath well before refilling
Circulation is broken down
5.4.1.2 Too high a density
Bath temperature too high
Developing time too long
Exposure time is too long
Replenishment rate of developer too high
Developer chemicals are too high diluted: Renew
After renewing chemicals: Starter is missing
Circulation is broken down
5.4.1.3 Films will not dry
If warm air comes out of the air channel in the dryer, chemicals and film type should be
checked
Fixer solution is exhausted or diluted
5.4.1.4 Film has a yellow-green surface
Not fixed correctly. Check the film type and fixer chemistry
Fixer solution is exhausted or diluted. Replenishment rate of fixer is too low
5.4.1.5 Scratches, pressure marks, dirt on film
Prior to processing films, run cleaner films through the processor
Pressure marks caused by careless handling, finger nails etc.
Rollers are polluted. Clean tanks and roller racks
5.4.1.6 Cloudy film
Level in developer is too low
First guide bar of fixer rack is dirty (condensate or crystals). Clean roller racks
Developer is old or circulation not working
Try processing films by infeeding them with emulsion side up