the manual mode, see Fehler! Verweisquelle konnte nicht gefunden werden.„Manual
starting and stopping the fil transport“.
CAUTION!
Ensure correct seating of roller racks; keep the lock closed at all times.
Don’t operate processor with empty replenishment tanks.
After a long machine shut down check bath level and refill if necessary.
5.5 Error messages
Machine errors are shown on the display as abbreviations. The cause of error is explained below. For
service technician: problem solution see “Trouble shooting” capture 7.
Display Cause and possible correction
E1
Cover switch is not actuated. Place cover correctly on the machine and
ensure that the cover switch behind the control panel is actuated. If the
error cannot be corrected, then the cover switch may be defective.
E2
Motor servo
-
control defective, call service technician. In the meantime
work can be continued with the last set processing speed. The processing
speed cannot be altered. (Service see “Error messages” see 7.3.3).
E3
Drive
-
overload, take off machine cover and remove all
roller racks
. Check
each rack for easy rotation of the drive shaft. If necessary clean roller-racks
and machine. Error can be reset by switching the machine off. If the need
arises let a service technician check the machine. If the above measures do
not improve the situation, the motor may be defective.
E4
Error:
Over temperature
in dryer section. Call your service technician. Dryer
components could be broken. Machine can only be used in manual mode,
and the dryer fan runs continuously (error will always be displayed). The
machine may only be operated under constant supervision. Check if air is
coming out from the opening in the cover. If no air comes out, the fan is
defective and the machine may not be used. Switch the machine off.
Error can only be reset by switching the processor off (Service see “Display
shows error message E4”” see Fehler! Verweisquelle konnte nicht
gefunden werden.).
LO
Input locked. To change operation parameters the lock function must be
deactivated (see “Lock Function” see 5.2.15)