7. RADIO CODES
The control panel DOESN’T ALLOW TO STORE any remote control if SAFETY DEVICES are DISCONNECTED.
Make sure input no. 2 STOP (DL5), input no. 5 photocell in OPENING (DL7) and input no. 6 photocell in CLOSING (DL8)
are connected.
Led OFF = input DEACTIVATED
Led ON = input ACTIVED
IIf no safety device has been wired, proceed to bridge temporarily the terminal according to chapter 3.6.1.
The control panel has been designed to operate with fixed code or rolling-code remote controls.
Choose the remote control you wish to store carefully: once the remote control has been saved and memorized,
the control panel shall only recognize that kind of radio code without possibility of reset.
Before starting proceed to delete all existing radio codes.
7.1 DELETING EXISTING RADIO CODES
- Press SET-TX and keep pressed for 10 seconds (DL1 blinks).
- DL1 turns off. All codes have been deleted.
7.2 LOADING A REMOTE CONTROL AS START COMMAND
- Press SET-TX once: DL1 blinks (1 blink – stop – 1 blink ….)
- Load within 5 sec. the remote control you wish to store.
The control panel has stored the radio code and goes out the programming automatically.
You can store a maximum of 32 different radio codes (Start + Pedestrian + 2° radio channel)
7.3 LOADING A REMOTE CONTROL AS PEDESTRIAN COMMAND
- Press SET-TX twice. DL1 blinks (2 blinks – stop – 2 blinks ….)
- Load within 5 sec. the remote control you wish to store.
The control panel has stored the radio code and goes out the programming automatically.
7.4 LOADING A REMOTE CONTROL AS 2° RADIO CHANNEL COMMAND (MRX01 jack)
- Press SET-TX three times. DL2 blinks (3 blinks – stop – 3 blinks ….)
- Load within 5 sec. the remote control you wish to store.
The control panel has stored the radio code and goes out the programming automatically.
PROTECO S.r.l. Via Neive, 77 - 12050 Castagnito (CN) ITALY Tel. +39 0173 210111 - Fax +39 0173 210199 info@proteco.net - www.proteco.net

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Proteco myGate Q81A and is the answer not in the manual?

Proteco myGate Q81A Specifications

General IconGeneral
BrandProteco
ModelmyGate Q81A
CategoryControl Panel
LanguageEnglish

Related product manuals