3.4.6.8 ELECTRODES SETTING
The electrodes must be adjusted by a qualified technician. A proper positioning
of the electrodes is important to get an efficient lighting of the oil and and efficient
dispersion of the oil jet
3.4.6.9
ELECTRODE SETTING FOR "F" HEAD
7/16"
5/32"
1/16"
NOZZLE
ELECTRODE