Enforcer Programming Manual
Page: 22
4.16.6 Strobe/Squawk at Set:
If 'STROBE', any output programmed as 'STROBE ANY' will activate for 5 seconds after the
Enforcer 32-WE has set. If 'SQUAWK' any output programmed as 'SIREN ANY' will activate for 5
seconds after the Enforcer 32-WE has set, and if 'BOTH' then any outputs programmed as
STROBE ANY or SIREN ANY will activate for 5 seconds after the Enforcer 32-WE has set.
NOTE: If this function is enabled, a potential security risk could be in view for intruders to see.
4.16.7 Autoset Force:
If 'YES', and an auto set timer is programmed on the InSite upload/download software, then the
Enforcer 32-WE will set on an auto set regardless of any inputs being open during the setting
period.
4.16.8 Restrict PIN use:
If 'YES', the Enforcer 32-WE prevents a PIN code being entered on the Entry time, but allows a
PIN code to silence any alarm that may occur.
NOTE: Enable when BS8243 option 6.4.5 is in use
4.16.9 Simple Set
If 'YES', the Enforcer 32-WE allows a user to set the system 'quickly' by pressing and then
the Area (A, B, C or D).
NOTE: This must not be enabled when BS8243 option 6.4.5 is in use.
4.16.10 2 Key HU:
If the 1 and 7 keys are pressed and held together for a period of time (programmed in the
keypad menu, see page: 14), a 'Hold Up' will occur.
If 'NONE', the keys are disabled. If 'SILENT', a 'Silent Hold Up' will be signaled. If 'Bells Only',
any external sounder will activate but NO signals will be sent. If 'BOTH', any external sounder
will activate and a signal will be sent using a Digi 1200 (PSTN) or Digi GSM.
4.16.11 Tag Opens Doors
This function is only be used in conjunction with a reader being programmed as 'Entry Control' is
in 'ASSIGN KEYPADS/READERS' (see page: 14).
If 'YES' the 'Entry Control' readers will control the setting/unsetting and the doors. If 'NO' the
Entry Control readers will control the setting/unsetting only.
4.16.12 Fire Key Enable
If 'YES' the fire key will be enabled on the Enforcer 32-WE keypad.
4.16.13 Set With Polling Fault
If ‘YES’ the Enforcer 32-WE will set the system if there is a wireless polling fault. The Enforcer
32-WE will display a wireless polling fault but will allow the user to set the system.
If 'NO' the user will not be able to set the Enforcer 32-WE with a polling fault. The Enforcer 32-
WE will display a fault and the arming procedure will be stopped.
4.16.14 Fob Unset Entry
If 'YES' any wireless keyfobs learnt will only be able to unset the Enforcer 32-WE once the entry
time time has been activated. If ‘NO’ any wireless keyfobs learnt will always be able to set and
unset the Enforcer 32-WE.
4.16.15 Wireless Bell Supervision
If 'YES' then the wireless external sounder (DELTABELL-WE) will go into alarm if it can no longer
communicate with the Enforcer 32-WE.
4.16.16 Download if Set
If 'YES' any upload/download procedures will be possible on the InSite software regardless of the
set/unset status of the Enforcer 32-WE.