NOTE 1: Inform the user that Signalling and SMS costs will incur and they should contact their
network provider if they have any questions.
NOTE 2: The more content types enabled, and the more areas enabled, the more costs will
incur.
NOTE 3: If a Digi-GSM is installed (opposed to a Digi-1200), then the communication formats
that can only be used are: Fast Format, SMS message and Contact ID. The string "1st
ARC/SMSCI 07785499993" will not be displayed either. If this is displayed, the Digi GSM is not
connected to the Enforcer 32-WE.
NOTE 4: To add a pause when programming a telephone number, press until a comma is
displayed.
4.22.2 Programming Digi Channels
The communication protocol 'Fast Format type 4.8.1' is commonly used for BSIA Fast Format
signalling. The channels for Fast Format can be individually programmed in this function. Each
channel uses a programmable output number (see Appendix D, page: 51)
NOTE: The communicator “status channel” (channel 0) is used for low voltage and test calls.
4.22.3 Advanced SMS Details
This function is used to enter an 'Account Reference' if required when using SMS messaging.
There is a 'Manufacturer's Access' area that can be used to change the 'Castle Host Computer'
(CHC) number. To have this access please contact customer support.
4.22.4 Prefix Number
The prefix telephone number is an extra digit required to reach the Enforcer 32-WE if needed,
For example, dial 9 to get an ‘outside’ line.
4.22.5 3 Way Calling
For future use.
Program ARC/SMS: SMS Programming
1. Press or to scroll to 'PROGRAM ARC/SMS'. Press .
2. 'Program ARC/SMS Calls will be displayed. Press to program
the SMS numbers and event types.
3. 'ARC/SMS is' will be displayed. Use [ or ] to enable or disable
signalling and press .
4. 'ARC Details' will be displayed. Select the ARC account to be
programmed (1-4) and press .
5. 'Active' will be displayed. Use [ or ] to enable or disable the
ARC number and press .
6. 'Format' will be displayed. Enter [133] for SMS messaging and
press .
7. '1st ARC/SMS' will be displayed (only if using a Digi-1200 PSTN
modem). DO NOT DELETE. Press .
8. 'Mobile Number' will be displayed. Enter the mobile number that
receive all signalling events and press .
9. 'Valid Area's' will be displayed. Select the areas that the mobile
number will be applicable to and press .
10. 'Content' will be displayed. Select the content types that will be
signaled and press . Repeat for content types 17-32 and press
.
11. 'Redials' will be displayed. Enter the number of redials required if
the number programmed is not answered and press .
12. 'Time Out' will be displayed. Enter the time and press .
13. 'ARC Details' will be displayed and another number can be
programmed if required. Press to return to the sub-menu. If a
pre fix number is required, keep pressing until 'Prefix Tel No.'
is displayed and enter the number and press .
PROGRAM
ARC/SMS?
Program ARC/SMS
Calls?
ARC/SMS is
Disabled [1]
ARC Details
[1]
Format [133]
SMS Message
1st ARC/SMSCI
07785499993
Mobile No
Content 1-16
.....6..........
Redials
[03]

Table of Contents

Other manuals for Pyronix Enforcer 32-WE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Enforcer 32-WE and is the answer not in the manual?

Pyronix Enforcer 32-WE Specifications

General IconGeneral
BrandPyronix
ModelEnforcer 32-WE
CategorySecurity System
LanguageEnglish

Related product manuals