Page: 51
Appendix D. Output Types
Type Active Restore
0000 Not Used (permanently off)
0001 Fire At alarm When a valid code is entered
0002 Hold Up Any
At a HU or Duress alarm
(This includes keypad HU)
When a valid code is entered
0003 Intruder Any
At alarm, while system is
disarmed
At first valid code entry and at
end of confirm time.
0005 Misoperation Any (Abort)
When system is silenced after
any ‘intruder’ output is
triggered
After 2 minutes
0006 Confirmed Any
After two ‘intruder’ alarm
activations
At next code entry
0007 Tamper Any Any tamper alarm
At code entry to silence
And at end of confirm time.
0008 Duress
At a Duress alarm (i.e. from a
keypad)
When a valid code is entered
0009 HU Device Any At alarm on a HU input only When a valid code is entered
0010 Gas At alarm When a valid code is entered
0011 Set Fail
Pre-set time after start of exit
time, if exit procedure is not
complete
At code entry to rearm
0012 Entry Deviation
When deviation from entry
route occurs, during entry time
At code entry to unset
0013 Secure Intruder Any
At alarm, after exit time
started, until unset
At first valid code entry
and at end of confirm time.
0014 Siren Any When alarm live
When alarm silenced or when
siren timer expires
0016 Strobe Any When alarm live
When alarm silenced or when
strobe timer expires
0017 Omit Rearm Any
Input omitted if active (or in
alarm condition) at the end of
confirmation time.
When system disarmed
0018 Unconfirmed Any Any intruder or Tamper alarm At code entry to silence
0021 Exit Starts Any
When exit time starts to set
FIRST area
At code entry to unset LAST
area
0022 Final Set Any When FIRST area is set
At code entry to unset LAST
area
0023 Strobe Set Fail
Works similar to output 016, but also fires if the set fail timer
expires.
0025 Keyswitch unset
This output turns on for 5 seconds when the system is disarmed
via a keyswitch input (pulsed or latched)
0026 Set with Omit Activates when inputs are omitted on setting
0028 Power Fault
Active during low volts and battery faults
*. Restores at code
entry after fault cleared.
0029 Confirmed Intruder Any
When more than one intruder
alarm activates
At next code entry
0030 Confirmed Hold Up Any
When more than one
confirmed hold up activates
At next code entry
0033 Entry/Exit Live during any entry or exit time