! Matrix 832 / 832+ / 424
RINS428-5 Page 147
12.11.4 Normally Closed Zones to Matrix 832
NVM Reset
Relay
17V~ +BAT- B+ B- BT GT NC C
NO1/
PGM1
PGM2
PGM3
PGM4
KD Z1 Z2 Z3 Z4
COM
COM
+AUX- Z5 Z6 Z7 Z8
COM
COM
RING
TIP
R-1
T-1
1
7
v
A
.
C
.
O
u
t
p
u
t
+
-
B
A
T
+
A
U
X
-
+
N
/
C
T
T
+
N
/
C
T
T
+
A
U
X
-
Spare
C
N
Zone 7
Zone 8
Magnum Ultra
Door Contact
Zone 6
12.11.5 Double End of Line Resistors to Matrix 832
NVM Reset
Relay
17V~ +BAT- B+ B- BT GT NC C
NO1/
PGM1
PGM2
PGM3
PGM4
KD Z1 Z2 Z3 Z4
COM
COM
+AUX- Z5 Z6 Z7 Z8
COM
COM
RING
TIP
R-1
T-1
Any unused zones
should be linked by a
4k7 resistor
Spare
C
N
MAGNET
PERSONAL ATTACK
BUTTON
Door Contact
+
A
U
X
-
Spare
C
N
+
N
/
C
T
T
+
N
/
C
T
T
+
A
U
X
-
1
7
v
A
.
C
.
O
u
t
p
u
t
+
-
B
A
T
Zone 7
Zone 8
Magnum Ultra
Magnum Ultra
4k7
4k7
4k7
4
k
7
4
k
7
4
k
7
4
k
7
4
k
7
4
k
7
4
k
7
4
k
7
4k7
Zone 1
Zone 2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Matrix Series and is the answer not in the manual?

Pyronix Matrix Series Specifications

General IconGeneral
BrandPyronix
ModelMatrix Series
CategoryControl Panel
LanguageEnglish

Related product manuals