! Matrix 832 / 832+ / 424
RINS428-5 Page 59
7.10 System Faults & Tamper Alarms Warning Allocation
PC Programming Procedure
The PC window below shows how to assign system faults and tamper alarms to a partition from the PC
software. Once an option has been chosen, press <save> and proceed to the next window.
MEANING
Programmable Options Explanation
Active in Partition
System faults Notification Partition Allocation
This option allows the engineer to program which partitions in the system will be able to display system faults.
“0” stands for disable.
Bell and Tamper Faults Partition Notification
This option allows the engineer to program which partitions in the system will be able to display bell and
tamper faults. “0” stands for disable.
SUPPLY
FAU L T
ARMED
P.A.READY
TAMPER
FIRE
DAY
ALARM
8
8
BCD
2
1
34
ET
FUNC
P.
.
FIRE
5678
90
Keypad Programming Procedure
7.10.1 System Faults (Warning Partition Allocation)
Enter BUZ. The current setting will be displayed. Enter partition numbers [0]* or [1 - 4]. To allocate
system faults notification to. To save the changes press
B. An acceptance tone will be heard.
*[0] = 0 as the first partition will cause system faults to display in all partitions.
7.10.2 Bell And Tamper Faults (Warning Partition Allocation)
Enter BUZ. The current setting will be displayed. Enter partition numbers ([0]* or [1 - 4]) to allocate
tamper notification to. To save the changes press
B. An acceptance tone will be heard.
*[0] = 0 as the first partition will cause system faults to display in all partitions.