BMC MAINTENANCE GROUP
4-72
Procedure:
Click Enter Update Mode to upgrade the current device firmware. As below step by step:
1. Closing all active client requests.
2. Preparing device for firmware upgrade.
3. Uploading firmware image.
4. Verifying firmware image.
5. Flashing firmware image.
6. Resetting Device.
BIOS Update
This page allow user to update BIOS image, but only works when DC is off. Please note the
filename extension of BIOS image shall be bin. For example: BIOS3A22.bin. After BIOS
update complete, system must perform AC cycle to take effect.
Figure 4-52. BIOS Update Page
Preserve Configuration
This page allows the user to configure the preserve configuration items, which will be
used by the Restore factory defaults to preserve the existing configuration without over-
writing with default configuration.
Item Verification Procedure
1. SDR
Step 1: add OEM record ( Please refer to IPMI 2.0 Spec. page 468/644)
Note:
You can now follow the instructions presented in the subsequent pages to successfully update
the card’s firmware. The device will reset if update is canceled. The device will also reset upon
successful completion of firmware update.

Table of Contents