41
DS-1200 G4i Operator Manual Issue 4 - Nov 2020
7.1.4 Saving the Job
1 Press the keyboard button and enter a job name using the on-screen
keyboard.
Repeat for a brief job description for the job. This will appear in the job list.
2 If required, enter further settings as described below.
Job number control mode: If Job Numbers are being used, select how these
are generated. If Manual entry (external checking) is selected, enter the
job number in the box underneath.
AIMS mode: Select what AIMS is to be used for (if applicable). Options are:
Statistics / Audit / Verication / Lookup (FBM). Verication and Lookup (FBM)
will only be available if Job Number Control Mode is an external source, either
Manual entry (external) or Read from prime.
Datalogging mode: Select whether O, Standard (default) or AIMS
statistics compatible.
Late divert: This uses customer’s own data le to divert using the ID eld
label instead of the Divert BCS Character. Options are O (default) or On (all).
Checking: If Checker required is selected, a checker is required to login at
the same time as the operator. The checker is responsible for conrming, job
settings, processing etc.