EasyManua.ls Logo

rada DRV40 - Common Fault: Outlet Temperature Fluctuations; Diagnosing Fluctuations and Mechanism Checks

rada DRV40
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
60
Stop Valve
Full Bore Isolating Valve
Pressure Reducing Valve
Shower
Thermometer
Cold Water
Hot Water
Mixed Water
Check Valve
Recirculation Pump
Key
Strainer / Filter
Needle Valve
Flow indicator
Safety Valve
Water
Heater
Problem: “Outlet temperature uctuates more than ± 2°C...”
Check internal mechanism
Mechanism is jamming or slow to control.
Clean and descale the following parts:
Proportioning Assembly
Gear Drive Assembly
Magnetic Rotor
Renew separator seal and lubricate internal
mechanism.
Water pressure
Make sure supply pressures are balanced.
Check for the following:
Air locks
Blocked strainers
Closed valves

Related product manuals