Select the setting item "ABP" by pressing “Dec(-)” or “Inc(+)” button,then press
“Enter” key and the initial value of “ABP” will blink. Use “Dec(-)” or Inc(+) button
to adjust the return amount.
(Note: In the interface of adjusting the value, return to the initial value"50" by
pressing “Dec(-)” and Inc(+)” buttons simultaneously for about 1 second.)
Press “Enter” button, the adjusted value stops blinking, now the value has been set.
"0":No return
"50":Return to the 50% position of the brake operation amount
"100":Return to the neutral position.
Brake return amount (ABP)
0 ~ 50 ~ 100
Initial value; 50
- Brake return amount (ABP) is influenced by the "EXP" rate on the brake side.
2. (Delay amount setup)
Select the setting item "DLY" by pressing “Dec(-)” or “Inc(+)” button, then press
“Enter” key and the initial value of “DLY” will blink. Use “Dec(-)”or Inc(+) button
to adjust the delay amount.
(Note: In the interface of adjusting the value, return to the initial value "0"by pressing
“Dec(-)” and Inc(+)” buttons simultaneously for about 1 second.)
Press “Enter” button, the adjusted value stops blinking, now the value has been set.
"0":A.B.S. function performed without any delay
"50":A.B.S function performed after an approximate 0.7 sec delay
"100":A.B.S. function performed after an approximate 1.7 secs delay
Delay amount (DLY)
0 ~ 100
Initial value; 0