Operating Manual 1302.6163.12 - 03 4.283
R&S ESU Instrument Functions
Basic Settings
Serial Interface Configuration
COM
INTERFACE
The COM INTERFACE softkey activates the COM INTERFACE table for entry of the
serial interface parameters.
The following parameters can be configured in the table:
Baud – Data transmission rate
The R&S ESU supports baud rates between 110 and 128000 baud. The default set-
ting is 9600 baud.
Remote command: SYST:COMM:SER:BAUD 9600
Bits – Number of data bits per word
For the transmission of text without special characters, 7 bits are adequate. For
binary data as well as for text with special characters, 8 bits must be selected
(default setting).
Remote command: SYST:COMM:SER:BITS 7
Baud rate data transmission rate
Bits number of data bits
Parity bit parity check
Stop bits number of stop bits
HW-Handshake hardware handshake protocol
SW-Handshake software handshake protocol
Owner assignment to the measuring instrument or computer