Operating Manual 1302.6163.12 - 03 6.103
R&S ESU Remote Control – Description of Commands
DIAGnostic Subsystem
DIAGnostic<1|2>:SERVice:HWINfo?
This command queries the contents of the module info table. Table lines are output as string data and
are separated by commas.
"<component 1>|<serial #>|<order #>|<model>|<HWC>|<rev>|<sub rev>",
"<component 2>|<serial #>|<order #>|<model>|<HWC>|<rev>|<sub rev>", ...
The individual columns of the table are separated from each other by '|'.
The numeric suffix <1|2> is ignored with this command.
Example: "DIAG:SERV:HWIN?"
Result (shortened):
"RF_ATTEN_7|650551/007|1067.7684|02|00|20|04",
"IF-FILTER|648158/037|1093.5540|03|01|07|05",
...
Characteristics: *RST value: --
SCPI: device-specific
Mode: R, A