EasyManua.ls Logo

R&S ESU Series - Page 550

R&S ESU Series
855 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Manual 1302.6163.12 - 03 6.111
R&S ESU Remote Control – Description of Commands
DISPlay Subsystem
DISPlay[:WINDow<1|2>]:TRACe<1...3>:Y:SPACing LINear | LOGarithmic| LDB
This command toggles between linear and logarithmic display in the selected measurement window.
On a linear scale, switch over between the unit % (command DISP:WIND:TRAC:Y:SPAC LIN) and
the unit dB (command DISP:WIND:TRAC:Y:SPAC LDB) is also possible.
If the FM demodulator (R&S FS-K7) is active and result display AF spectrum of FM, AM or PM is
selected, only the parameters LINear and LOGarithmic are permissible.
The numeric suffix in TRACe<1...3> is irrelevant.
Example: "DISP:TRAC:Y:SPAC LIN"
Characteristics: *RST value: LOGarithmic
SCPI: conform
Mode: A
DISPlay[:WINDow<1|2>]:TRACe<1...3>:Y:UNIT?
This command returns the Y unit that has been set.
This command is only a query and has the *RST value from the UNIT:POWer command.
The numeric suffix in TRACe<1...3> has no significance.
Example: "DISP:WIND1:TRAC:Y:UNIT?"
Characteristics: *RST value: DBM
SCPI: device-specific
Mode: A
DISPlay[:WINDow<1|2>]:TRACe<1...3>:MODE WRITe | VIEW | AVERage | MAXHold | MINHold
This command defines the type of display and the evaluation of the traces in the selected
measurement window. WRITE corresponds to the Clr/Write mode of manual operation.
The trace is switched off (= BLANK in manual operation) with the DISPlay[:WINDow<1|2>]:
TRACe<1...3>[:STATe] command.
The number of measurements for AVERage, MAXHold and MINHold is defined with the [SENSe<1|2>:
]AVERage:COUNt or [SENSe<1|2>:]SWEep:COUNt command.
Synchronization to the end of the indicated number of measurements is only possible in single-sweep
mode.
If calculation of average values is active, selection between logarithmic and linear averaging is
possible. For more detail see command [SENSe<1|2>:]AVERage:TYPE.
Example: "INIT:CONT OFF"
'Switching to single-sweep mode.
"SWE:COUN 16"
'Sets the number of measurements to 16.
"DISP:WIND1:TRAC3:MODE MAXH"
'Switches on the calculation of the for trace 3 in screen A.
"INIT;*WAI"
'Starts the measurement and waits for the end of the 16 sweeps.
Characteristics: *RST value: WRITe for TRACe1, STATe OFF for TRACe2/3
SCPI: device-specific

Table of Contents

Related product manuals