R&S ESU Remote Control – Description of Commands
SENSe Subsystem
6.210 Operating Manual 1302.6163.12 - 03
6.16.13 SENSe:SCAN Subsystem
This subsystem controls the parameters for the receiver scan data.
The numeric suffix in [SENSe<1|2>:]SCAN selects the scan range. The measurement window is
selected by SENSe1 (screen A) and SENSe2 (screen B).
[SENSe<1|2>:]SCAN<1 to 10>:STARt f
min
to f
max
This command defines the start frequency of the selected receiver scan range.
Example: ":SCAN1:STAR 50kHz"
'Sets the start frequency of scan range 1 to 50 kHz
Characteristics: *RST value: 150 kHz (range1)
30 MHz (range2)
SCPI: device-specific
Mode: R
[SENSe<1|2>:]SCAN<1 to 10>:STOP f
min
to f
max
This command defines the stop frequency of the selected receiver scan range.
Example: ":SCAN1:STOP 200kHz"
'Sets the stop frequency of scan range 1 to 200 kHz
Characteristics: *RST value: 30 MHz (range1)
1 GHz (range2)
SCPI: device-specific
Mode: R
[SENSe<1|2>:]SCAN<1 to 10>:STEP f
min
to f
max
This command defines the step size for the frequency of the selected receiver scan range.
Example: ":SCAN1:STEP 100Hz"
'Sets the step size for the frequency of scan range 1 to 100 Hz
Characteristics: *RST value: 4 kHz (range 1)
40 kHz (range 2)
SCPI: device-specific
Mode: R
[SENSe<1|2>:]SCAN<1 to 10>:BANDwidth:RESolution 10 Hz to 10 MHz
This command defines the bandwidth for the selected receiver scan range.
Example: ":SCAN1:BAND:RES 1MHz"
'Sets the resolution bandwidth of scan range 1 to 1 MHz
Characteristics: *RST value: 9 kHz (range 1)
120 kHz (range 2)
SCPI: device-specific
Mode: R