8 | iZoneControl
Operating instructions 47 / 92
8 iZoneControl
With iZoneControl you can divide the pan base into individual heating zones and operate these with different
temperatures; unused surfaces can even stay cold. You specify the desired result and start the cooking process for
each heating zone. The heating zone will now be heated to the optimal temperature leading to your desired result.
NOTICE
The temperature difference between the zones should not be more than 130 °C.
Pan division
Ticket selection window
Zone
Heating surface
Actions
Edit presets
Pan allocation
8.1 Tickets
8.1.1 Preset tickets
There are preset tickets for the different cooking modes available for you to use.