6 | Electrical connection
36 / 52 80.06.415_iVario2-XS-iVarioPro2-S_IM_en_US
5. Press lightly on the cover in the area of the relevant screw and tighten the
screws (5) and (6) one after the other.
6. Put the silicone caps on the screws.
>> The electrical compartment is closed and protected against water and
moisture penetration.
6.7 Connected loads of different voltage types
Maximum connection voltage
n
Maximum permissible tolerance for the input voltage: - 10% to 10%
n
The device can be used with frequencies of 50 Hz and 60 Hz without tech-
nical modifications.
3 AC 440 V Power kW Power consump-
tion A
Fuse A Conductor cross-sec-
tion AWG
iVario 2-XS 13 17 25 14
iVario Pro 2-S 19 25 35 10
3 AC 208 V Power kW Power consump-
tion A
Fuse A Conductor cross-sec-
tion AWG
iVario 2-XS 15 48 60 6
iVario Pro 2-S 23 64 70 6