9 | Waste water connection
80.06.415_iVario2-XS-iVarioPro2-S_IM_en_US 47 / 52
6. When connecting the drain pipe in the wall, the installation altitude must be
between 150–300mm [5 7/8–11 3/4 inch].
150–300 mm
5 7/8–11 3/4 Inch
7. Position the cover and screw in the 2 screws.
>> The drain pipe is connected watertight to the unit drain.
>> The drain pipe is connected with a constant incline of at least 5 % or 3°.
>> The cover for the connections is screwed on to the device.
Installing the wastewater connection with drain to the front side of the device
When installing the wastewater drain to the front side of the device, a device
foot height of 90 mm [3 1/2 Inch] is required.
The drain pipe is fixed on the adjustable foot with a mounting clip. The fixing for
the wastewater pipe is included in the device connection kit.
a The adjustable foot is mounted with a height of 90 mm [3 1/2 Inch].
a There is a drainage channel with a waste grating in front of the device.