2
Manual No. 016-0159-831 9
Introduction
For Example:
Based on these calculations and a PSI of 30, tip XR8004 should be selected since it comes closest to
providing the desired output.
Verifying Flow Rate Limits
The flow rate of spray must be within the specified range for the flow meter being used.
*Note: Only Krohne Magmeters sold through Raven Industries should be used with Raven controllers. No
other Krohne Magmeters are supported.
Nominal Application Pressure 30 PSI (kpa)
Target Application Rate 20 GPA (lit/ha)
Target Speed 5.2 MPH (km/h)
Nozzle Spacing 20 inches (cm)
20 GPA x 5.2 MPH x 20 inches = .35 GPM
5,940
Flow Meter Model Flow Range
RFM 5 0.1 - 5 GPM [0.2 - 18.9 lit/min]
RFM 15 0.3 - 15 GPM [1.1 - 56.8 lit/min]
RFM 60P 1 - 60 GPM [3.8 - 210 lit/min]
RFM 60S 1 - 60 GPM [3.8 - 210 lit/min]
RFM 100 5 - 100 GPM [18.9 - 380 lit/min]
RFM 200/200 Poly 15 - 200 GPM [56.8 - 760 lit/min]
Magmeter 200 3 - 200 GPM [11.36 - 757 lit/min]
RFM 400 25 - 400 GPM [94.6 - 1515 lit/min]
Krohne 3” Magmeter* 15 - 250 GPM [56.78 - 946.25 lit/min]
Krohne 4” Magmeter* 35 - 1,800 GPM [132.48 - 6813 lit/min]
Krohne 6” Magmeter* 70 - 3,000 GPM [264.95 - 11,355 lit/min]

Table of Contents

Other manuals for Raven SCS 450

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raven SCS 450 and is the answer not in the manual?

Raven SCS 450 Specifications

General IconGeneral
BrandRaven
ModelSCS 450
CategoryControl Systems
LanguageEnglish

Related product manuals